How do concealed sprinkler heads work




















Pendant heads would normally be used when there is not sufficient space above the ceiling of behind the wall to fit a concealed sprinkler head. When concealed sprinkler heads are exposed to heat from a fire, the cover plate, which is normally soldered to the support cup at three points, falls away to expose the sprinkler assembly.

At this point the deflector supported by the arms drops down to its operating position. The sprinkler heads is now ready to actuate if the temperature continues to rise. We have over 20 years experience in designing, manufacturing and installing high quality fire protection equipment to ensure your property is safe from the threat of fires.

Facebook Twitter. This allows for a quick reaction to a fire and is the most common type of sprinkler installed in buildings. A type of building that uses the wet pipe system is a high-rise or office building with a few floors.

Each individual sprinkler head is triggered automatically when the air rising to the ceiling reaches a fire-specific temperature of to degrees. Often, only one or two sprinklers are required to fully extinguish a building fire. The basic difference between fire-preventive upright sprinklers and pendant sprinklers is the position each takes on a water pipe. An upright sprinkler , as its name implies, stands atop the pipeline, whereas a pendant type hangs from the pipe.

At different pressures, the sprinkler head and nozzle will consume different amounts of water. If your home's water capacity was 10 GPM, you could place 3 heads per zone. Minimum Distance Between Sprinklers : typically 6'-0". Distance from Ceiling: minimum 1", maximum 12" for unobstructed construction. The minimum 1" is typical; however, concealed, recessed, and flush sprinklers may be mounted less than 1" from the ceiling and shall be installed based on their listing.

Sprinkler per Branch line limit. In the case of the extended coverage heads the square footage can range between square feet per sprinkler head. The most important application when using extended coverage heads is based on the recent testing using the EC sprinklers. How does a concealed sprinkler head work? Category: home and garden smart home. A residential concealed fire sprinkler head is a 'fast response', two stage devise, the size of a down light.

In the event of a fire reaching its operating point, the flat plate will drop from the devise and the deflector plate of the sprinkler head will then drop below the ceiling level. What triggers a sprinkler head? How far does a sprinkler head spray? How many pop up sprinklers can I run? How many types of sprinklers are there?

The solder is temperature sensitive to melt usually 20 degrees Fahrenheit lower than the sprinkler head activation temperature.

When the solder melts, the cover plate falls off allowing the sprinkler head deflector to drop below the ceiling height and distribute the water after the sprinkler activates. According to NFPA 13, 25 and code, concealed sprinkler heads in ceilings must have the proper fitting cover plate assembly.

Missing, damaged or improper fitting fire sprinkler head cover plates allow heat and smoke to rise up through the gap and may delay the activation of the sprinkler head. Furthermore, if smoke detectors are present, their activation could be delayed, jeopardizing early detection and life safety. Occasionally cover plates fall off or become damaged and just like sprinkler head escutcheons, never paint the cover plates.

Also, never try to glue or caulk a cover plate in place. Remember that cover plates are manufactured and listed, as part of the concealed fire sprinkler head assembly.